The SOA (Safe Operating Area) tool calculates the internally dissipated
power of a WEI device in your system. To prevent damage to the WEI device's
output stage, operate below the maximum internal power specification. Note
that this is a simulation. As with all thermal designs, allowing some
overhead is a best practice.
| Application Specifications | |
| Date Generated: | 2026-07-30 10:27:45 PM UTC |
| Product: | LD15CHA |
| Required Thermal Option: | MULTI-HTSK-HI |
| Max. Enclosure Temperature: | 25° Celsius |
| Limit Current: | 12 Amps |
| Maximum Current For Product: | 15.00 Amps |
| Series Impedance: | 5 Ω |
| Laser Threshold Voltage: | 7 VDC |
| Supply Voltage: | 18 VDC |
| Minimum Supply Voltage For Product: | 5.00 VDC |
| Maximum Supply Voltage For Product: | 30.00 VDC |
| LEGAL DISCLAIMER: While reasonable care has been taken to ensure the
accuracy of this simulation, Wavelength Electronics Inc shall not be liable for
any direct, indirect, special, incidental, or consequential damages, whether
based on contract, tort, or any other legal theory. Copyright © 2008-2018 by Wavelength Electronics, Inc. | |