Skip to content

QUESTION

ANSWER

If the PD is isolated from the LD then it is a B type laser. If your supply output ground can float in reference to earth ground you can make standard connections as shown for CC mode in the WLD3343 Datasheet/Manual or WLD33ND & WLD33ND-EV Evaluation Board Datasheet. If the supply can not be isolated from earth ground then you must use a negative power supply and connect it as shown in the attached diagram. If you use a negative supply you must use a negative voltage for pin 2 (current input setting) or you can add the op amp as shown to invert the signal for use with a D/A.

Laser Class Schematic
Laser Class Schematic